Green Energy
Home Insulation Building Science Energy Services Jobs Green Energy

 

Up

Biomass Heating and Cooling

BIOMASS CHEAPER THAN FOSSIL FUEL- Download Dec 1. 2005 Press release PDF

Natural gas is $15.00 per mmbtus. Propane costs $20.00 per mmbtus. Electric heating costs $30.00 per mmbtu. Conventional firewood at $100 per cord delivers heat at under $10.00 per mmbtu when burned efficiently (84%). If you have access to wood, consider being a Heating Entrepreneur in your rural community. The average rural school spends over $150,000 a year on propane, why not spend that money for firewood produced by the local community?  A Coop for rural Heating Entrepreneurs is being studied, see www.heat.coop

Althouse is the exclusive New Mexico dealer for Garn boilers. High efficiency  combustion of  a variety of low cost fuels with integrated thermal storage for 24 hour a day comfort. Go to the Garn website http://www.dectra.net/garn/Wood_heat.htm

   1450  1900  3200
Width x Height (inches) 72" x 76" 72" x 76" 86" x 93"
Overall Length
 102" 126" 156"
Recommended wood length
 24-32  24-32  32-48
Weight - filled, pounds
 15,000  20,000  34,000
Approximate gallons of storage
 1,500  2,000  3,200
Firebox length
 42  42  52
Btu/hr into storage*
 350,000  425,000  915,000
Btu's stored
120º- 200º F
 920,000  1,334,000  2,135,000

*Btu/hr storage is extremely fuel dependent. These numbers based on the use of split, 16" oak with 20% moisture and a reloading once an hour.

GARN® equipment is certified to burn; cord or slab wood; pallet and other scrap wood; densified wood briquettes; and air dried corn on the cob.

 

 

As part of a program of continuous product improvement, DECTRA CORPORATION reserves the right to change models, specifications and pricing without notice. GARN® is a Registered Trademark.


 

Why does a GARN® WHS unit perform so well?

Combution air is drawn directly from outdoors through an internal air inlet tube (A) to the air distribution collar (B). The door (C) prevents air from being drawn from the room. The door is insulated to prevent heat loss and includes an air-cooled heat shield to prevent hot surfaces near the user. Combustion air from the collar flows through an upper and lower nozzles (D) into the combustion chamber (E). Remaining free air is mixed with hot gases before entering the ceramic secondary combustion chamber (F). Within the ceramic chamber, smoke, creosote and particulates are burned at temperatures near and above 2000 ºF. The hot gases release their heat as they move through a 5 pass tubular heat exchanger (G) submerged within a large volume of water. The cooled gases are then pulled into the Draft Inducer housing (H) and pushed out of the exhaust pipe (I).

 

Adsorption Cooling

Althouse is the New Mexico source for adsorption cooling systems that use the Garn boiler in the summer to provide chilled water for air conditioning. Eliminate high air conditioning electric bills and the accompanying high on peak demand charges. Visit http://www.adsorptionchiller.bigstep.com/ for more information about our air conditioning systems. 

 

 

bulletWater used as refrigerant, no freons, no Li-Br, no ammonia means : No hazardous leaks, no corrosion, no chemical testing, no replacement.
bulletNo compressor means: No alignment, no high voltage, no high pressure, no overhaul, no oil change, no surging, no vibration or noise.
bulletStable chilled water out-put driven by a wide range (194 to 122oF) of hot water.
bulletCapacity out-put remains stable as in-put fluctuates. No back up burner required
bulletSimple and short start up / stop time
bullet38 F of chilled water is in the standard specification.
bulletConstant operation - 24 hours / 7 days a week.

 

 

 

 

Send mail to webmaster@althouse.biz with questions or comments about this web site.